Your browser doesn't support javascript.
loading
A Biomechanical Analysis on Disc Pressure Distribution Changes with Interspinous Spinal Spacer Insertion for Lumbar Spinal Stenosis / 대한정형외과학회잡지
The Journal of the Korean Orthopaedic Association ; : 789-794, 2007.
Article in Korean | WPRIM | ID: wpr-656784
ABSTRACT

PURPOSE:

To assess the biomechanical effects and effectiveness of an interspinous spinal spacer (ISS) on the intradiscal pressure using in vitro biomechanical tests. MATERIALS AND

METHODS:

Six calf spine specimens (less than 2 weeks of age, L1-L5) were divided to two groups the intact and the surgery groups (n=3 each). For the surgery group, an ISS made from PMMA (Greek pi=12-mm) were inserted into the space between the spinous processes of L3-L4. The intradiscal pressures at the various regions of the annulus (anterior, posterior, and posterolateral locations) and the nucleus pulposus were measured using the four pressure transducers under pure compression (700 N) and extension loads (700 N+7.5 Nm).

RESULTS:

An increase in pressure was observed from neutral to extension at the posterior and posterolateral annulus. After inserting the ISS, the changes in pressure at the adjacent disc levels (L2-L3, L4-L5) were negligible regardless of the loading conditions (p>0.05). However, at the implanted level (L3-L4) statistically significant changes in the pressure were found under extension loading at the nucleus pulposus, posterior and posterolateral regions of the annulus with a pressure drop from 1.48 MPa, 1.42 MPa, 1.71 MPa to 1.11 MPa, 0.961 MPa, 1.08 MPa, at the respective locations (p<0.05). The relative percentage decrease were 25%, 31.7%, and 36.8%.

CONCLUSION:

On the implanted level, these results showed that the insertion of the ISS with PMMA can effectively reduce the intradiscal pressures by at least 25% quite uniformly over the intravertebral disc during extension. More effective reduction was observed at the posterolateral location. The pressure changes at the adjacent levels were negligible in contrast to the abnormal pressure changes that are frequently reported after conventional rigid fusion. This suggests that the likelihood of adjacent level degeneration after surgery can be minimized using the ISS insertion.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Spinal Stenosis / Spine / Transducers, Pressure / Polymethyl Methacrylate Language: Korean Journal: The Journal of the Korean Orthopaedic Association Year: 2007 Type: Article

Similar

MEDLINE

...
LILACS

LIS