Determination of Antioxygen 1178 in 5-Layer Co-extrusion Bags Used for Infusion by HPLC / 中国药师
China Pharmacist ; (12): 876-877, 2015.
Article in Zh | WPRIM | ID: wpr-669785
Responsible library: WPRO
ABSTRACT
Objective:To establish a method for the determination of antioxygen 1178 in 5-layer co-extrusion bags used for infu-sion. Methods:A Uitimat XB-C8 (250 mm × 4. 6 mm,5μm) column was used,the mobile phase was methanol-water with gradient elu-tion, the flow rate was 1. 0 ml·min-1 ,the detection wavelength was 223 nm,the column temperature was 35℃ and the injection vol-ume was 20 μl. Results:The concentration of antioxygen 1178 had the linear relationship within the range of 1. 64-205. 10 μg·ml-1 (r=0. 999 9),and the average recovery was 92. 05% (RSD=1. 94%, n=9). Conclusion:The method is accurate,stable and spe-cific,and can be used to determine antioxygen 1178 in 5-layer co-extrusion bags used for infusion.
Key words
Full text: 1 Index: WPRIM Language: Zh Journal: China Pharmacist Year: 2015 Type: Article