Determination of Residual Organic Solvents in Salvianolic Acid B by Headspace GC / 中国药师
China Pharmacist
;
(12): 865-866,867, 2015.
Article
in Chinese
| WPRIM
| ID: wpr-671125
ABSTRACT
Objective:
To establish a method to determine the residual solvents in salvianolic acid B.Methods:
The headspace GC was carried out on an HP-5 capillary column(30 m × 0. 32 mm,0. 6 μm). The inlet temperature was 180℃. The injection volume was 0. 1ml and the separation ratio was 110. The column temperature was programmedthe initial temperature was 40℃, malntalned for 6 min, ralsed to 180℃ with a rate of 15 ℃·min-1 , and malntalned for another 5 min. The detector was FID with the temperature of 250℃. The carrier gas was N2 with the flow rate of 1. 7 ml·min-1 . DMSO was used as the solvent for salvianolic acid B.Results:
All solvents could be separated completely. The linear range of ethanol, acetone and ethyl acetate was 12. 650-1. 012 × 103 μg·ml-1 (r=0.999 3),12.750-1.012 ×103 μg·ml-1(r=0.999 7) and 12.550-1.004 ×103 μg·ml-1(r=0.999 7), respectively. The average recovery of ethanol, acetone and ethyl acetate was 96. 89% (RSD=3. 81%,n=9), 99. 56% (RSD=4. 05%,n=9) and 97. 21% (RSD=4. 95%,n=9), respectively.Conclusion:
The method is simple, reproducible and accurate enough for the determi-nation of residual solvents in salvianolic acid B.