ABSTRACT
Standard electrical quantity (a), chronaxie (?), rheobase (Rh), "b" in Weiss' formula and intensity threshold of duration being 40 ?s and 300 ?s (T_(?) and T_(200)) were measured on peroneus nerves in rabbits. The results show that "a" is an actual index for measuring the excitability of various groups of fibers. The larger fibers, the higher excitability and the smaller "a" values. "b" does not indicate excitability. "?" , "Rh" , "T_(40)" and "T_(200)" are not actual indexes for measuring excitability because they are influenced by "b" in Weiss' formula.