Your browser doesn't support javascript.
loading
MEASUREMENT OF EXCITABILITY OF VARIOUS FIBERS IN PERONEUS NERVE IN RABBITS STANDARD ELECTRICAL QUANTITY (a) AS AN ACTUAL INDEX FOR MEASURING EXCITABILITY / 西安交通大学学报(医学版)
Journal of Xi'an Jiaotong University(Medical Sciences) ; (6)1982.
Article in Chinese | WPRIM | ID: wpr-674497
ABSTRACT
Standard electrical quantity (a), chronaxie (?), rheobase (Rh), "b" in Weiss' formula and intensity threshold of duration being 40 ?s and 300 ?s (T_(?) and T_(200)) were measured on peroneus nerves in rabbits. The results show that "a" is an actual index for measuring the excitability of various groups of fibers. The larger fibers, the higher excitability and the smaller "a" values. "b" does not indicate excitability. "?" , "Rh" , "T_(40)" and "T_(200)" are not actual indexes for measuring excitability because they are influenced by "b" in Weiss' formula.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Journal of Xi'an Jiaotong University(Medical Sciences) Year: 1982 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Journal of Xi'an Jiaotong University(Medical Sciences) Year: 1982 Type: Article