Your browser doesn't support javascript.
loading
Application of Cook MOB-15 system in guiding wire insertion during endoscopic retrograde cholangiopancreatography / 第二军医大学学报
Academic Journal of Second Military Medical University ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-680461
ABSTRACT

Objective:

To evaluate the value of Cook MOB-15 system in guiding wire insertion during endoscopic retrograde cholangiopancreatography (ERCP).

Methods:

The clinical data of 51 patients who received Cook MOB-15 system-guided wire insertion during ERCP between Jan. 2005 to Dec. 2007 were retrospectively analyzed. Forty patients who received conventional ERCP catheter for malignant jaundice between Jan. 2002 and Dec. 2004 were taken as control. The successful insertion rates were compared between the 2 groups.

Results:

The successful insertion rate was 90.2% (46/51) in the Cook MOB-15 system group and 72.5% (29/40) in the conventional group; there was significant difference between the 2 groups (P

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Academic Journal of Second Military Medical University Year: 2001 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Academic Journal of Second Military Medical University Year: 2001 Type: Article