Evaluation of the Performance of Two Kinds of Anti-TP Enzyme-Linked Immunosorbent Assay / 中国实验血液学杂志
Journal of Experimental Hematology ; (6): 905-910, 2018.
Article in Chinese | WPRIM | ID: wpr-689555
ABSTRACT
<p><b>OBJECTIVE</b>To evaluate the accuracy and precision of 2 kinds of anti-treponema pallidum (anti-TP) ELISA reagents in our laboratory for detecting the anti-TP in voluntary blood donors, so as to provide the data support for use of ELISA reagents after introduction of chemiluminescene immunoassay (CLIA).</p><p><b>METHODS</b>The route detection of anti-TP was performed by using 2 kinds of ELISA reagents, then 546 responsive positive samples detected by anti-TP ELISA were collected, and the infections status of samples confirmed by treponema pallidum particle agglutination (TPPA) test was identified. The confirmed results of responsive samples detected by 2 kinds of anti-TP ELISA reagents were compared, the accuracy of 2 kinds of anti-TP ELISA reagents was analyzed by drawing ROC and comparing area under curve (AUC), and precision of 2 kinds of anti-TP ELISA reagents was compared by statistical analysis of quality control data from 7.1 2016 to 6.30 2017.</p><p><b>RESULTS</b>There were no statistical difference in confirmed positive rate of responsive samples and weak positive samples between 2 kinds of anti-TP ELISA reagents. The responsive samples detected by 2 kinds of anti-TP ELISA reagents accounted for 85.53%(467/546) of all responsive samples, the positive rate confirmed by TPPA test was 82.87%. 44 responsive samples detected by anti-TP ELISA reagent A and 35 responsive samples detected by anti-TP ELISA reagent B were confirmed to be negative by TPPA test. Comparison of AUC showed that the accuracy of 2 kinds of anti-TP ELISA reagents was more high, the difference between 2 reagents was not statistically significant. The coefficient of variation (CV) of anti-TP ELISA reagent A and B was 14.98% and 18.04% respectively, which met the precision requirement of ELISA test.</p><p><b>CONCLUSION</b>The accuracy and precision of 2 kinds of anti-TP ELISA reagents used in our laboratory are similar, and using any one of anti-TP ELISA reagents all can satisfy the requirements of blood screening.</p>
Subject(s)
Full text: Available Index: WPRIM (Western Pacific) Main subject: Treponema pallidum / Blood Donors / Enzyme-Linked Immunosorbent Assay / Syphilis Serodiagnosis Type of study: Diagnostic study Limits: Humans Language: Chinese Journal: Journal of Experimental Hematology Year: 2018 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Treponema pallidum / Blood Donors / Enzyme-Linked Immunosorbent Assay / Syphilis Serodiagnosis Type of study: Diagnostic study Limits: Humans Language: Chinese Journal: Journal of Experimental Hematology Year: 2018 Type: Article