Effect of high-intensity alternating magnetic field on viscosity of sheep blood / 中南大学学报(医学版)
Journal of Central South University(Medical Sciences) ; (12): 1395-1400, 2017.
Article in Chinese | WPRIM | ID: wpr-693758
ABSTRACT

Objective:

To explore the changes of blood viscosity in high-intensity alternating magnetic field and the mechanisms.

Methods:

Five adult sheep were randomly selected and the blood samples were placed in highintensity alternating magnetic field.Before and after exposure,the blood samples were taken and divided into 2 groupsa control group and a magnetic field group.The blood rheology and transmission electron microscopy (TEM) were performed.

Results:

Compared to the control group,the high shear viscosity of whole blood was decreased in the magnetic field group (P<0.05);the whole blood low shear viscosity and plasma viscosity were also decreased (both P<0.01).TEM showed the changes in red blood cell morphology and the double concave disc curvature.The radian of double concave disc and cell volume in the magnetic field group was larger than those in the control group.

Conclusion:

The high intensity alternating magnetic field may affect the distribution of surface charge and molecular current in blood cells,which in turn decrease the aggregation of cells and the blood viscosity.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Journal of Central South University(Medical Sciences) Year: 2017 Type: Article