Your browser doesn't support javascript.
loading
Application of 70 kV tube voltage combined with low dose and low concentration of contrast medium in CCTA / 实用放射学杂志
Journal of Practical Radiology ; (12): 431-434, 2018.
Article in Zh | WPRIM | ID: wpr-696835
Responsible library: WPRO
ABSTRACT
Objective To access the effects of 70 kV tube voltage combined with low dose and low concentration of contrast medium in coronary CT angiography (CCTA)by evaluating the image quality,radiation dose and contrast medium dosage.Methods Ninety patients suspected with coronary artery disease with body mass index(BMI)of less than 25 kg/m2and heart rate (HR)of less than 75 beats per minute were enrolled.The patients were randomly divided into three groups (n=30 for each group):Group A,100 kV of tube voltage with 370 mg I/mL iopromide,1 mL/kg;Group B,80 kV with 270 mg I/mL iodixanol,1 mL/kg;Group C,70 kV with 270 mg I/mL iodixanol,0.8 mL/kg.All the patients underwent CCTA with a 256 row wide-coverage volumetric CT.Automatic tube current modulation technique was applied.The images were reconstructed by adaptive statistical iterative reconstruction V (ASIR-V).The subjective image quality scores were compared with rank-sum test.The signal-to-noise ratio (SNR),contrast-to-noise ratio(CNR),effective dose(ED)and the total iodine intake were calculated and compared with one-way ANOVA.Results No statistically differences in age,gender,heart rate and BMI were observed among the three groups (P>0.05).Subjective image quality scores had no difference among the three groups (P>0.05).The CT values of group C were higher than those of group A(P<0.05).The image noise of group C was higher than that of group A and group B (P<0.05).No significant differences in SNR and CNR were noticed among the three groups (P>0.05).The ED of group B (0.39±0.08)mSv and group C (0.19±0.01)mSv were lower than that of group A (0.81±0.19)mSv (each P<0.05).Compared with group A,the decrease rates of ED of group B and C were 51.8% and 76.5% respectively.Compared with group A and group B,the total iodine intake of group C was decreased by 25% and 21.4% (P<0.05).Conclusion 70 kV of tube voltage combined with low dose and low concentration of contrast medium in CCTA can reduce the radiation dose and iodine intake without compromising image quality.
Key words
Full text: 1 Index: WPRIM Language: Zh Journal: Journal of Practical Radiology Year: 2018 Type: Article
Full text: 1 Index: WPRIM Language: Zh Journal: Journal of Practical Radiology Year: 2018 Type: Article