Your browser doesn't support javascript.
loading
One-lung ventilation with pediatric Arndt endobronchial blocker in an adult patient with tracheal stenosis: A case report
Anesthesia and Pain Medicine ; : 353-356, 2011.
Article in English | WPRIM | ID: wpr-69748
ABSTRACT
In thoracic surgery, functional isolation of the lungs can be accomplished by several methods. However, for patients with tracheal stenosis, only limited choices are available to achieve one-lung ventilation (OLV) because of the difficulties posed by the stenotic trachea. In our patient, the narrowest site in the trachea was as small as 9.3 mm in diameter, and therefore a 28 Fr double-lumen endotracheal tube (DLT) or a Univent tube (inner diameter [ID] 6.0 mm) could not be inserted into the trachea. Recently, 7 and 9 Fr Arndt endobronchial blockers (AEB) used in adults could not even be used in our patient. Here we report a case of successful OLV that was performed using a pediatric wire-guided AEB and a small diameter single lumen endotracheal tube (SLT). We believe that this pediatric AEB is a safer and more effective option for achieving OLV in adult patients with tracheal stenosis.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Thoracic Surgery / Trachea / Tracheal Stenosis / One-Lung Ventilation / Lung Limits: Adult / Humans Language: English Journal: Anesthesia and Pain Medicine Year: 2011 Type: Article

Similar