Your browser doesn't support javascript.
loading
Methodological validation: a method for Determination of Iodine in Serum-As3+-Ce4+ Catalytic Spectrophotometry / 中华地方病学杂志
Chinese Journal of Endemiology ; (12): 579-583, 2018.
Article in Chinese | WPRIM | ID: wpr-701381
ABSTRACT
Objective To carry out a methodological validation of a new standard method "Determination of Iodine in Serum-As3+-Ce4+ Catalytic Spectrophotometry".Methods In accordance with the requirements of "Guide for Establishing Occupational Health Standards-Part 5Determination Methods of Chemicals in Biological Materials (GB/T 210.5-2008)",the methodological validation was tested in 3 standard development and 3 verification laboratories,calculated the linear relation and range of standard curve and the lowest linmit of detection,precision,accuracy and anti-interference ability,sample stability of sample determination.Results The linear range of iodine mass concentration of the standard curve was 0 to 300 μg/L in 6 laboratories.The linear correlation coefficients of the standard curve obtained from each laboratory were 0.999 1 to 1.000 0.The detection limits of serum iodine were 1.8 to 6.9 μg/L (the.sample amount was 0.10 ml) in 5 laboratories.Precision15 different serum samples from 5 laboratories with a total iodine concentration range of 48.8 to 273.2 μg/L were repeatedly tested for six times,the relative standard deviations (RSD) were 0.7% to 3.8% (the average was 1.7%).Accuracya total recovery of samples with iodine concentrations ranging from 26.3 to 253.3 μg/L were performed in 5 laboratories,the recoveries were 96.2% to 105.2% (the average was 99.8%).One laboratory carried out the standard method and the inductively coupled plasma mass spectrometry (ICP-MS) method for serum iodine determination.The recovery rates of the two methods were 96.4% ~ 107.8%,which met the measurement requirements.Anti-interference15 kinds of chemical reagents were added for interference test in 3 laboratories,and the results showed no deviation,indicating that the standard method had strong anti-interference.StabilityThe samples could be stored for 7 days at room temperature,for 2 months at 4 ℃,and for 3 months after freezing when the assay results were not affected.Reaction temperature and timethe appropriate pairing budget for temperature and time was consistent with the standard method.Conclusion The verification of the standard method for serum iodine determination further proves that the standard method has the advantages of simple reagents preparation,wide linear range,better correlation coefficient,lower detection limit,higher precision and accuracy,stronger antiinterference ability,convenient batch testing,and wide applicability.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Endemiology Year: 2018 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Endemiology Year: 2018 Type: Article