Simultaneous Determination of Taurine and Aminocaproic Acid in Compound Taurine Eye Drops by High Performance Liquid Chromatography-Refractive Index Detector / 中国药师
China Pharmacist ; (12): 919-922, 2018.
Article in Chinese | WPRIM | ID: wpr-705628
ABSTRACT

Objective:

To establish an HPLC-RID method for the simultaneous determination of taurine and aminocaproic acid in compound taurine eye drops.

Methods:

A Waters NH2column(250 mm ×4.6 mm,5 μm) was used, the mobile phase was water-acetonitrile (4060) at a flow rate of 0.8 ml·min-1, the column temperature was 35.0℃, and the temperatures of the detector reference cell and the sample cell were both set at 35.0℃,The injection volume was 20 μl.

Results:

The linear ranges of taurine and aminocaproic acid were 0.05-2.00 mg·ml-1(r = 0.999 9). The average recovery was 98.57% (RSD = 1.07%,n= 9) and 100.69% (RSD =0.75%,n =9),respectively.

Conclusion:

The established method is accurate,simple and rapid, and suitable for the quality control of compound taurine eye drops.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacist Year: 2018 Type: Article