The observation on the clinical effect of CSEA by using orbital needle external needle in PCEA post cesarean delivery / 中国医学装备
China Medical Equipment ; (12): 95-98, 2018.
Article in Chinese | WPRIM | ID: wpr-706555
ABSTRACT

Objective:

To observe the clinical effect of combined spinal epidural anesthesia(CSEA)by using orbital needle in patient-controlled epidural analgesia(PCEA)post cesarean delivery.

Methods:

94 puerperas who received cesarean were divided into observation group(47 cases)and control group(47 cases).The patients of two groups were narcotized by using CSEA combined with PCEA.And the observation group adopted a new type of lumbar vertebral combined puncture needle and the control group adopted the traditionally typical lumbar vertebral combined puncture needle.The score of visual analogue scale(VAS)and sedation score of Ramesay of two groups of postoperative 1h,4h,12h,24h and 48h were compared.And the number of times in 48h,the drug dosage and adverse reaction of using analgesia pump also were compared.

Results:

In postoperative 12 h,the VAS scores of the two groups showed an increasing trend.And the VAS scores of pain of two groups within postoperative 12-48 h decreased gradually.The differences of VAS scores of pain of two groups within postoperative 1-12h and 12-48h between observation group and control group were statistically significant(F=29.596,F=156.366,P<0.05),respectively.And the VAS scores of pain post operative 4h and 12h of observation group [(2.01±0.51)and(3.49±0.74)]were significantly lower than that of control group [(2.32±0.47)and(3.85±0.69)](t=3.064,t=2.439,P<0.05),respectively.Within postoperative 1-48h,there were no significant fluctuation in sedation score of Ramesay and the difference of sedation score between the two groups were no significant.And the number of times(11.35±3.04)and drug dosage(65.67± 7.98)mL of using analgesic pump of observation group were significantly lower than that of control group [(20.08±5.32)and(82.07 ± 9.05)mL],(t=9.768,t=9.318,P<0.05),respectively.Besides,the incidences of postoperative nausea and skin pruritus of observation group(4.26%and 14.89%)were significantly lower than that of control group(17.02%and 34.04%)(x2=4.029,x2=4.663,P<0.05),respectively.

Conclusion:

The analgesia effect of orbital needle external needle in implementing CSEA for cesarean delivery is better than that of traditional needle inner needle,and its adverse reactions are less and it is safety.