Your browser doesn't support javascript.
loading
Comparison of the Sliding and Femoral Head Rotation among Three Different Femoral Head Fixation Devices for Trochanteric Fractures
Article in En | WPRIM | ID: wpr-70758
Responsible library: WPRO
ABSTRACT
BACKGROUND: Recently, various femoral head fixation devices (HFDs) for trochanteric fractures have become available. However, there are some cases in which femoral head rotation with excessive sliding of the HFD is observed and it is often followed by cutout. The purpose of this study is to compare the ability of the three types of HFDs to prevent femoral head rotation. METHODS: Between July 2005 and December 2009, 206 patients aged over 60 years with trochanteric fractures who had undergone surgical treatment using a short femoral nail in our institution were enrolled into the study. We used the gamma 3 nail (GMN) as the screw-type HFD in 66 cases, the gliding nail (GLN) as a non-cylindrical blade in 76 cases, and the proximal femoral nail antirotation (PFNA) as a cylindrical blade in 64 cases. The sliding length of HFDs and the occurrence of femoral head rotation were evaluated by assessing radiographs as the main outcome, and the results were compared among these devices. RESULTS: A comparison of the degree of sliding in the GMN group showed that femoral head rotation was observed significantly more frequently in cases with rotation. Further, it appeared that femoral head rotation occurred more frequently in comminuted fractures. However, no significant differences between the sliding lengths of the different HFDs were observed among three groups. Femoral head rotation was observed in 15 cases of GMN (22.7%), 0 case of GLN, and 5 case of PFNA (7.8%). Significant differences with regard to the occurrence of femoral head rotation were observed among the three groups. Furthermore, significant differences were also observed between GLN and PFNA with respect to the occurrence of femoral head rotation. CONCLUSIONS: The ability to stabilize femoral head appears to be greater with blade-type materials than with screw-type materials. Furthermore, we believe that a non-cylindrical blade is preferable to a cylindrical blade for the surgical treatment of comminuted, unstable trochanteric fractures in order to prevent femoral head rotation and cut-out.
Subject(s)
Key words
Full text: 1 Index: WPRIM Main subject: Postoperative Complications / Retrospective Studies / Internal Fixators / Range of Motion, Articular / Femur Head / Hip Fractures Type of study: Observational_studies Limits: Aged / Aged80 / Female / Humans / Male Language: En Journal: Clinics in Orthopedic Surgery Year: 2015 Type: Article
Full text: 1 Index: WPRIM Main subject: Postoperative Complications / Retrospective Studies / Internal Fixators / Range of Motion, Articular / Femur Head / Hip Fractures Type of study: Observational_studies Limits: Aged / Aged80 / Female / Humans / Male Language: En Journal: Clinics in Orthopedic Surgery Year: 2015 Type: Article