Your browser doesn't support javascript.
loading
The medium-term outcomes of three-dimensional printing uncemented prosthesis replacement for giant cell tumor of distal radius / 中华骨科杂志
Chinese Journal of Orthopaedics ; (12): 851-858, 2018.
Article in Chinese | WPRIM | ID: wpr-708603
ABSTRACT
Objective To explain the concept and surgical technique of 3D printing uncement radius distal prosthesis,evaluate and discuss the medium-term outcome of the prosthesis for giant cell tumor in distal radius.Methods From September 2015 to March 2017,13 patients diagnosed as giant cell tumor in distal radius were performed with en bloc resection combined with 3D print uncement prosthesis.All patients graded Campanacci Ⅲ or occurred local recurrence.Two patients with local recurrence had a local lesion curettage,inactivation and bone cement filling.There were 7 males and 6 females,with an average age of 37.8 years.Through the preoperative three-dimensional CT data,the 3D model of the distal radius was obtained based on the contralateral radius and the 3D printing uncemented distal radius prosthesis was made.Directly reconstrucion was conducted if the wrist joint ligament and joint capsule can be preserved.The surrounding soft tissue,remaining joint ligament and joint capsule were sutured to the prosthesis together combined with a brace if the wrist joint ligament and joint capsule can be only preserved partially.Radiocarpal joint was temporarily fixed by Kuntscher pin if the wrist joint ligament and joint capsule can't be preserved completely.Results In our series,the average resection length of the distal radius measured from the radial styloid process was 65.54±6.70mm.The length of prosthesis was consistent with the resection length and the length ratio of prosthesis to prosthetic stem is 11.The follow-up time was 17.77±4.97 months.There were no local recurrence and metastasis.At the end of the followup,except waist flexion,the wrist extension,wrist pronation,wrist supination,hand grip strength and Mayo wrist were significantly improved from 41.69°± 11.35°,41.92°± 11.09°,40.00°±7.64°,16.84±6.28 mmHg,47.69±9.27 points preoperatively to 57.46°±17.18°,55.00°±17.91°,53.46°±19.30°,23.08±6.29 mmHg,70.00±11.55 points,respectively.The DASH score was significantly decreased from 32.07±6.71 points to 19.15±8.41 points postoperatively.During surgery,there was one patient received temporary wrist fixation with kirschner's needle,which got a relatively poor postoperative function.Excluding this patient,comparing the resuits of 8 cases with directly suturing of wrist joint ligament and joint capsule and that of 4 cases with reconstructing by suturing and fixing with a brace,there were no statistical differences.There were no wrist dislocation or subluxation,aseptic prosthesis loosening,wrist joint degenerative changes or other prosthesis related complications.Conclusion 33D printing uncemented distal radius prosthesis is a good choice for the Campanacci grade Ⅲ or recurrent giant cell tumor in distal radius,because of its personalized design and uncemented fixation;in clinical application,we should pay attention to the evaluation of preoperative wrist joint capsule and surrounding ligament and the intraoperative soft tissue repair techniques.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Prognostic study Language: Chinese Journal: Chinese Journal of Orthopaedics Year: 2018 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Prognostic study Language: Chinese Journal: Chinese Journal of Orthopaedics Year: 2018 Type: Article