Your browser doesn't support javascript.
loading
Analysis of setup errors during radiotherapy for breast cancer patients immobilized with neck and breast thermoplastic mask / 肿瘤研究与临床
Cancer Research and Clinic ; (6): 374-378, 2018.
Article in Chinese | WPRIM | ID: wpr-712832
ABSTRACT
Objective To analyze the setup errors by cone-beam computed tomography (CBCT) for breast cancer patients who were immobilized with neck and breast thermoplastic mask and received intensity modulated radiation therapy (IMRT), and to calculate the external margins from the clinical target volume (CTV) to the planning target volume (PTV) (MPTV) of tumors. Methods Twenty-five breast cancer patients who were immobilized with neck and breast thermoplastic mask and received IMRT in the Oncology Department of Tongji Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology from November 2016 to June 2017 were enrolled. The position of the patients were verified by CBCT before treatment . The linear and rotation errors of the X, Y and Z axes were analyzed by online bone registration. The systematic errors (Σ) and random errors (σ) of the patients were also calculated, and then the margins from CTV to PTV margins were calculated based on MPTV=2.5Σ+0.7σ. 25 patients'height, weight, body mass index (BMI) and the maximum diameters of CTV in the lateral, longitudinal and vertical directions were recorded, and the relation between the setup errors and the above mentioned was analyzed by using Spearman method. Results A total of 174 CBCT scans for 25 breast cancer patients were completed. The group Σ were 1.40 mm, 1.50 mm and 1.20 mm, and rotation errors were 0.9°, 0.7° and 0.8° at the X, Y and Z axes, respectively. The group σ were 2.20 mm, 3.00 mm and 1.40 mm, and rotation errors were 0.7°, 0.6° and 0.7° at the X, Y and Z axes, respectively. MPTVwas recommended as 4.90 mm, 6.00 mm and 3.90 mm at the X, Y and Z axes, respectively. There was no correlation between the height, weight, BMI of the patients and the setup errors (all P > 0.05). However, there was a significant correlation between the maximum lateral, longitudinal diameters of the CTV and the setup errors (rs= 0.406, P= 0.044; rs= 0.512, P= 0.009). Conclusions The neck and breast thermoplastic mask can improve the diagnostic accuracy of radiotherapy in breast cancer patients. The data of setup errors verified by CBCT can provide meaningful references for the setting of MPTV.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Cancer Research and Clinic Year: 2018 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Cancer Research and Clinic Year: 2018 Type: Article