Effect of Cataract Grade according to Wide-Field Fundus Images on Measurement of Macular Thickness in Cataract Patients
Korean Journal of Ophthalmology ; : 172-181, 2018.
Article in English | WPRIM | ID: wpr-714964
ABSTRACT

PURPOSE:

To investigate the effects of cataract grade based on wide-field fundus imaging on macular thickness measured by spectral domain optical coherence tomography (SD-OCT) and its signal-to-noise ratio (SNR).

METHODS:

Two hundred cataract patients (200 eyes) with preoperative measurements by wide-field fundus imaging and macular SD-OCT were enrolled. Cataract severity was graded from 1 to 4 according to the degree of macular obscuring by cataract artifact in fundus photo images. Cataract grade based on wide-field fundus image, the Lens Opacity Classification System III, macular thickness, and SD-OCT SNR were compared. All SD-OCT B-scan images were evaluated to detect errors in retinal layer segmentation.

RESULTS:

Cataract grade based on wide-field fundus imaging was positively correlated with grade of posterior subcapsular cataracts (rho = 0.486, p < 0.001), but not with nuclear opalescence or cortical cataract using the Lens Opacity Classification System III. Cataract grade was negatively correlated with total macular thickness (rho = −0.509, p < 0.001) and SD-OCT SNR (rho = −0.568, p < 0.001). SD-OCT SNR was positively correlated with total macular thickness (rho = 0.571, p < 0.001). Of 200 eyes, 97 (48.5%) had segmentation errors on SD-OCT. As cataract grade increased and SD-OCT SNR decreased, the percentage of eyes with segmentation errors on SD-OCT increased. All measurements of macular thickness in eyes without segmentation errors were significantly greater than those of eyes with segmentation errors.

CONCLUSIONS:

Posterior subcapsular cataracts had profound effects on cataract grade based on wide-field fundus imaging. As cataract grade based on wide-field fundus image increased, macular thickness tended to be underestimated due to segmentation errors in SD-OCT images. Segmentation errors in SD-OCT should be considered when evaluating macular thickness in eyes with cataracts.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Retinaldehyde / Cataract / Classification / Artifacts / Tomography, Optical Coherence / Signal-To-Noise Ratio / Iridescence / Fundus Oculi Limits: Humans Language: English Journal: Korean Journal of Ophthalmology Year: 2018 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Retinaldehyde / Cataract / Classification / Artifacts / Tomography, Optical Coherence / Signal-To-Noise Ratio / Iridescence / Fundus Oculi Limits: Humans Language: English Journal: Korean Journal of Ophthalmology Year: 2018 Type: Article