Measurement of the Optic Nerve Sheath Diameter with Magnetic Resonance Imaging and Its Association with Eyeball Diameter in Healthy Adults
Journal of Clinical Neurology ; : 345-350, 2018.
Article in English | WPRIM | ID: wpr-715689
ABSTRACT
BACKGROUND AND

PURPOSE:

The optic nerve sheath diameter (ONSD) is an indirect marker of the intracranial pressure, but the normal range of ONSD as measured using magnetic resonance imaging (MRI) and its associations with clinical parameters and the eyeball transverse diameter (ETD) remain unclear.

METHODS:

We included 314 healthy adults who underwent brain MRI examinations for health screening between June 2014 and September 2017. The ONSD and ETD of each eye were calculated using time-of-flight magnetic resonance angiography. Linear regression analyses were performed to assess the relationships between ONSD and variables including age, sex, height, weight, body mass index (BMI), mean arterial blood pressure (MABP), intraocular pressure (IOP), and ETD. We further investigated a normative value for the ONSD/ETD ratio and its associated factors.

RESULTS:

The mean ONSD and ETD were 4.71 mm [95% confidence interval (CI), 4.66–4.75 mm] and 21.24 mm (95% CI, 21.13–21.35 mm), respectively. Multiple linear regression analysis showed that ONSD was only associated with ETD (p < 0.001), with it being independent of age, sex, height, weight, BMI, MABP, and IOP. The ONSD/ETD ratio had a mean value of 0.22 (95% CI, 0.22–0.22), and was not correlated with age, sex, height, weight, BMI, MABP, or IOP.

CONCLUSIONS:

This study determined the normative value of MRI-based ONSD in healthy Korean adults. There was a strong correlation between the ETD and ONSD, which can be presented as the ONSD/ETD ratio. This parameter needs to be investigated further in disease populations.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Optic Nerve / Reference Values / Body Weight / Brain / Magnetic Resonance Imaging / Intracranial Pressure / Linear Models / Mass Screening / Magnetic Resonance Angiography / Arterial Pressure Type of study: Prognostic study / Screening study Limits: Adult / Humans Language: English Journal: Journal of Clinical Neurology Year: 2018 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Optic Nerve / Reference Values / Body Weight / Brain / Magnetic Resonance Imaging / Intracranial Pressure / Linear Models / Mass Screening / Magnetic Resonance Angiography / Arterial Pressure Type of study: Prognostic study / Screening study Limits: Adult / Humans Language: English Journal: Journal of Clinical Neurology Year: 2018 Type: Article