Your browser doesn't support javascript.
loading
Prospective Multicenter Study of the Challenges Inherent in Using Large Cell-Type Stents for Bilateral Stent-in-Stent Placement in Patients with Inoperable Malignant Hilar Biliary Obstruction
Gut and Liver ; : 722-727, 2018.
Article in English | WPRIM | ID: wpr-718114
ABSTRACT
BACKGROUND/

AIMS:

Although endoscopic bilateral stent-in-stent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic re-intervention. This study aimed to evaluate the technical accessibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction.

METHODS:

Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015.

RESULTS:

Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases of technical success. Stent occlusion occurred in 63.2% of the patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months postoperatively, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage.

CONCLUSIONS:

Large cell-type stents for endoscopic bilateral stent-in-stent placement had acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Stents / Drainage / Cholestasis, Intrahepatic / Prospective Studies / Cholangiopancreatography, Endoscopic Retrograde / Klatskin Tumor / Self Expandable Metallic Stents Type of study: Controlled clinical trial / Observational study / Risk factors Limits: Humans Language: English Journal: Gut and Liver Year: 2018 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Stents / Drainage / Cholestasis, Intrahepatic / Prospective Studies / Cholangiopancreatography, Endoscopic Retrograde / Klatskin Tumor / Self Expandable Metallic Stents Type of study: Controlled clinical trial / Observational study / Risk factors Limits: Humans Language: English Journal: Gut and Liver Year: 2018 Type: Article