Your browser doesn't support javascript.
loading
Spatial reproducibility of complex fractionated atrial electrogram depending on the direction and configuration of bipolar electrodes: an in-silico modeling study
The Korean Journal of Physiology and Pharmacology ; : 507-514, 2016.
Article in English | WPRIM | ID: wpr-728680
ABSTRACT
Although 3D-complex fractionated atrial electrogram (CFAE) mapping is useful in radiofrequency catheter ablation for persistent atrial fibrillation (AF), the directions and configuration of the bipolar electrodes may affect the electrogram. This study aimed to compare the spatial reproducibility of CFAE by changing the catheter orientations and electrode distance in an in-silico left atrium (LA). We conducted this study by importing the heart CT image of a patient with AF into a 3D-homogeneous human LA model. Electrogram morphology, CFAE-cycle lengths (CLs) were compared for 16 different orientations of a virtual bipolar conventional catheter (conv-cath size 3.5 mm, inter-electrode distance 4.75 mm). Additionally, the spatial correlations of CFAE-CLs and the percentage of consistent sites with CFAE-CL<120 ms were analyzed. The results from the conv-cath were compared with that obtained using a mini catheter (mini-cath size 1 mm, inter-electrode distance 2.5 mm). Depending on the catheter orientation, the electrogram morphology and CFAE-CLs varied (conv-cath 11.5±0.7% variation, mini-cath 7.1±1.2% variation), however the mini-cath produced less variation of CFAE-CL than conv-cath (p<0.001). There were moderate spatial correlations among CFAE-CL measured at 16 orientations (conv-cath r=0.3055±0.2194 vs. mini-cath 0.6074±0.0733, p<0.001). Additionally, the ratio of consistent CFAE sites was higher for mini catheter than conventional one (38.3±4.6% vs. 22.3±1.4%, p<0.05). Electrograms and CFAE distribution are affected by catheter orientation and electrode configuration in the in-silico LA model. However, there was moderate spatial consistency of CFAE areas, and narrowly spaced bipolar catheters were less influenced by catheter direction than conventional catheters.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Atrial Fibrillation / Catheter Ablation / Electrophysiologic Techniques, Cardiac / Electrodes / Catheters / Heart / Heart Atria Limits: Humans Language: English Journal: The Korean Journal of Physiology and Pharmacology Year: 2016 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Atrial Fibrillation / Catheter Ablation / Electrophysiologic Techniques, Cardiac / Electrodes / Catheters / Heart / Heart Atria Limits: Humans Language: English Journal: The Korean Journal of Physiology and Pharmacology Year: 2016 Type: Article