Your browser doesn't support javascript.
loading
Application of Ic-VEP in diagnosis of early and middle stage glaucoma / 国际眼科杂志(Guoji Yanke Zazhi)
International Eye Science ; (12): 547-549, 2017.
Article in Chinese | WPRIM | ID: wpr-731437
ABSTRACT
@#

AIM:

To study the sensitivity and specificity of Ic-VEP in diagnose of early and middle stage glaucoma. <p>

METHODS:

All the participants included glaucoma patients and normal people came from Beijing Aier-Intech Eye Hospital from October 2014 to October 2016. All the participants performed slit lamp examination, fundus examination, Goldmann applanation tonometer, Humphery visual field examination, retinal nerve fiber layer(RNFL)thickness and macular ganglion cell complex(GCC)thickness examination and Ic-VEP. The sensitivity and specificity of Ic-VEP in diagnose of glaucoma were main results. <p>

RESULTS:

The sensitivity and specificity of Ic-VEP in diagnose of glaucoma is 82% and 92% respectively. The area under ROC curve was 0.872. Consistency of Ic-VEP and GCC thickness in moderate glaucoma was good(<i>Kappa</i> value=0.75). <p>

CONCLUSION:

Ic-VEP is a useful new method for the diagnosis of early and middle stage glaucoma.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study / Prognostic study Language: Chinese Journal: International Eye Science Year: 2017 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study / Prognostic study Language: Chinese Journal: International Eye Science Year: 2017 Type: Article