Your browser doesn't support javascript.
loading
99mTc-YIGSR as a Receptor Tracer in Imaging the Ehrlich Ascites Tumor-bearing Mice as Compared with 99mTc-MIBI / 华中科技大学学报(医学)(英德文版)
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 471-474, 2007.
Article in Chinese | WPRIM | ID: wpr-737187
ABSTRACT
The validity of 99mTc-YIGSR, a novel receptor radio-tracer, in imaging the Ehrlich ascites tumor was evaluated. YIGSR, a pentapeptide of laminin, was labeled with 99mTc by using a bifunctional chelator S-Acetly-NH3-MAG3. The MIBI was labeled with 99mTc by following the kit instruction. The mice of tumor group were intravenously injected 1-2 mCi of 99mTc-YIGSR or 99mTc-MIBI via caudal vein, immobilized and imaged under a Gamma camera. The same procedure was performed in mice of blockade group, in which the unlabeled YIGSR was previously injected to block the receptor-recognition sites, and inflammation group serving as control. The reverse-phase Sep-Pak C18 chromatogram was found to have an essentially complete conjugation between YIGSR and S-Acetly-NH3-MAG3. The conjugated YIGSR could be radio-labeled successfully with 99mTc at room temperature and neutral pH, with a radio-labeling yield of 62%. Without the chelator S-Acetly-NH3-MAG3, the YIGSR was labeled with 99mTc at an efficiency of 4%. The imagological study revealed obvious tumor accumulation of 99mTc-YIGSR 15 min after the injection, and the uptake peaked after 3 h with a tumor-to-muscle ratio (T/M) of 11.36. The radio-tracer was slowly cleared up and resulted in a T/M of 3.01 at the 8th h after the injection. As for blocked group, the tumor uptake of radiotracer was significantly lower, with the highest T/M being 4.61 after 3 h and 0.89 after 8 h. The T/M was 3.72 at the 3rd h and 1.29 at the 8th h after the 99mTc-YIGSR injection in the inflammatory group. The T/M was significantly higher in tumor group than in inflammatory group or control group (P<0.001). In the 99mTc-MIBI group, the T/M was 1.40 at the 3rd h and 0.55 at the 8th h after the injection, which showed a significant difference as compared with 99mTc-YIGSR (P<0.001).It is concluded that YIGSR can be successfully radiolabelled by using S-Acetly-NH3-MAG3.99mTc-YIGSR has many advantages in tumor imaging, such as quick and clear visualization, high sensitivity and specificity, and satisfactory target/non-target ratio (N/NT). It promises to be tumor radio-tracer.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Journal of Huazhong University of Science and Technology (Medical Sciences) Year: 2007 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Journal of Huazhong University of Science and Technology (Medical Sciences) Year: 2007 Type: Article