Your browser doesn't support javascript.
loading
Short Term Test-Retest Reliability of Contralateral Inhibition of Distortion Product Otoacoustic Emissions
Journal of Audiology & Otology ; : 189-196, 2018.
Article in English | WPRIM | ID: wpr-740345
ABSTRACT
BACKGROUND AND

OBJECTIVES:

Strength of medial olivocochlear reflex can be measured reliably using contralateral inhibition of distortion product otoacoustic emissions (DPOAEs) when its fine structure is considered. However, measurement of fine structure of DPOAE is difficult with clinical equipment. Thus, this study investigated the clinically relevant test-retest reliability of contralateral inhibition of DPOAEs. SUBJECTS AND

METHODS:

Twenty-six young adults with normal hearing sensitivity participated. DPOAEs were recorded at 27 discrete f2 frequencies between 800 Hz and 8,000 Hz at frequency resolution of 8 points per octave with and without contralateral white noise presented at 50 dB SPL. To check for short term inter-session reliability, contralateral inhibition of DPOAEs were recorded in three sessions, two recording sessions on first day separated by 30 minutes and third time after one week of the first session. Within each session, DPOAEs were recorded twice in single probe-fit condition to test for intra-session reliability.

RESULTS:

Cronbach’s alpha was calculated having poor reliability (α≤ 0.7) of contralateral inhibition of DPOAEs in both intra-session and inter-session conditions for most of the tested frequencies. 95% confidence intervals of contralateral inhibition magnitude also showed large variability.

CONCLUSIONS:

The current results showed that though DPOAE amplitudes were highly reliable across sessions, amount of inhibition of DPOAEs was not reliable when DPOAEs were measured at discrete frequencies. These findings are concurrent with the literature.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Reflex / Reproducibility of Results / Hearing / Noise Limits: Humans Language: English Journal: Journal of Audiology & Otology Year: 2018 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Reflex / Reproducibility of Results / Hearing / Noise Limits: Humans Language: English Journal: Journal of Audiology & Otology Year: 2018 Type: Article