Your browser doesn't support javascript.
loading
A case report of successful management of middle ear foreign body following hearing aid fitting with ossicular chains integrity / 临床耳鼻咽喉头颈外科杂志
Article in Zh | WPRIM | ID: wpr-746495
Responsible library: WPRO
ABSTRACT
A case of ear mold impression middle ear foreign body was reported. In the exploratory operation we found the ear mold impression surrounded the ossicular chains. During the process of removal the middle ear foreign body, the incudostapedial joint was protected from obvious external force and ossicular chains were kept integrity. Tympanoplasty was completed after management of foreign body. The patient recovered well postoperatively and was discharged as scheduled.
Subject(s)
Full text: 1 Index: WPRIM Main subject: General Surgery / Tympanoplasty / Ear, Middle / Ear Ossicles / Foreign Bodies Limits: Female / Humans Language: Zh Journal: Journal of Clinical Otorhinolaryngology Head and Neck Surgery Year: 2014 Type: Article
Full text: 1 Index: WPRIM Main subject: General Surgery / Tympanoplasty / Ear, Middle / Ear Ossicles / Foreign Bodies Limits: Female / Humans Language: Zh Journal: Journal of Clinical Otorhinolaryngology Head and Neck Surgery Year: 2014 Type: Article