Your browser doesn't support javascript.
loading
Characteristics of thrombelastography in term neonates and its comparison With traditional coagulation tests / 中华实用儿科临床杂志
Chinese Journal of Applied Clinical Pediatrics ; (24): 1064-1067, 2019.
Article in Chinese | WPRIM | ID: wpr-752354
ABSTRACT
Objective To explore the characteristics of thrombelastogaphy( TEG)in term neonates,and to evaluate their correlation with traditional coagulation tests. Methods A total of 52 term neonates were enrolled as neo-natal group and 34 adults undergoing elective surgery as adult control group in Jiangmen Central Hospital from January to December 2017. TEG,plasma coagulation test and platelet counts(PLT)were performed and the corresponding ana-lysis was conducted. Results TEG parameters in term neonatesresponse time(R)(4. 18 ± 1. 08)min,clot kinetics (K)(1. 21 ± 0. 45)min,α angle( Angle)(73. 08 ± 5. 74)°,maximum amplitude( MA)(65. 68 ± 7. 13)mm. Com-pared with adult control group,neonatal group exhibited shorter R and K(t=3. 764,P<0. 001;t=4. 888,P<0. 001), higher Angle,MA(t=5. 539,P<0. 001;t=2. 873,P=0. 001). In traditional coagulation,compared with adult control group,neonatal group showed longer prothrombin time( PT),activated partial thromboplastin time( APTT),thrombin time(TT)(t=5. 449,P<0. 001;t=13. 134,P<0. 001;t=3. 575,P=0. 001),lower fibrinogen( Fib)(t=4. 164, P<0. 001),and higher PLT(t=4. 230,P<0. 001). In addition,K was negatively correlated with Fib(r= -0. 374, P=0. 004),while Angle and MA were positively correlated with Fib(r=0. 354,P=0. 007;r=0. 630,P<0. 001);K was negatively correlated with PLT(r= -0. 430,P=0. 001),but Angle and MA were positively correlated with PLT (r=0. 427,P=0. 001;r=0. 586,P<0. 001);K was positively correlated with APTT(r=0. 285,P=0. 035),and MA was negatively correlated with APTT(r= -0. 324,P=0. 017). There was no significant correlation between R and tra-ditional coagulation test. K,MA and Angle were not significantly correlated with PT(all P >0. 05),and Angle and APTT were not significantly correlated(all P>0. 05). Conclusions The reference interval of TEG in term neonates is different from adults. And the parameters of TEG in term neonates are partly related to the traditional coagulation tests.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Applied Clinical Pediatrics Year: 2019 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Applied Clinical Pediatrics Year: 2019 Type: Article