Your browser doesn't support javascript.
loading
Clinical study of three‐dimensional transvaginal ultrasound in assessing abnormal position and adverse reactions of intrauterine device / 中华超声影像学杂志
Chinese Journal of Ultrasonography ; (12): 439-443, 2019.
Article in Chinese | WPRIM | ID: wpr-754825
ABSTRACT
Objective To investigate the incidence of abnormalities and adverse reactions of intrauterine device ( IUD) by three‐dimensional transvaginal ultrasound ,and guide the correct selection of IUD . Methods Female volunteers who came to our hospital for health check‐up from July 2016 to February 2018 were selected as subjects to obtain information of the belt loop time and number of loops . T hree‐dimensional transvaginal ultrasound was used to observe and record the IUD types and positions . T he incidence of location abnormalities ,adverse reactions and cervical lesions of differnet types of IUD were retrospectively analyzed . Results T wo thousand one hundred and thirteen eligible subjects were included in the study ,including 423 cases of McuIUD ,506 cases of circular ring ,405 cases of uterine ring ,372 cases of T‐ring and 407 cases of γ ring . T he statistical analysis showed that the incidence of adverse reactions after wearing rings was as high as 34 .07% ,and the adverse reaction rate of different IUD was different . McuIUD had the highest incidence of adverse reactions ,compared with the circular ring ,the uterine ring ,the T‐ring , and the γ ring ( 47 .99% vs 25 .88% ,27 .41% ,37 .10% ,33 .66% ; all P < 0 .05 ) . Different IUD had different incidence of adverse reactions . T he low back pain rate in McuIUD and γ ring were higher than the other 3 IUDs . T he low back pain rate of McuIUD was higher than the circular ring ,the uterine ring and the T‐ring ( 23 .4% vs 15 .71% ,14 .07% ,13 .7 1% ; all P < 0 .01 ) . Different types of IUD had different incidence of location anomalies . T he descending rate of the circular ring was higher than that of the McuIUD and γ ring ( 6 .32% vs 3 .30% ,3 .19% ; all P< 0 .05 ) ,and no statistically significant difference compared with the uterine ring and T‐ring ( 6 .32% vs 3 .45% ,4 .30% ; all P >0 .05 ) . T he incarceration rate of the mother ring was higher than that of the circular ring ,uterine ring and T‐ring ( 3 .07% vs 0 ,0 .25% ,0 .54% ;all P <0 .01) . T he intrauterine rotation rate of uterine ring and γ ring were higher than that of McuIUD , circular ring and T‐ring ( all P <0 .01) . Pregnancy >1 and ring times ≥2 were related with the occurrence of adverse reactions of IUD ( P < 0 .05 ) . T he incidence of cervical erosion in the T‐ring was the highest compared with the McuIUD ,circular ring ,uterine ring ,and γ ring ( 30 .65% vs 16 .78% ,16 .80% ,18 .02% , 17 .69% ; all P <0 .01) . Conclusions The incidence of adverse reactions is higher in women with different types of IUD . T he incidence of different types of abnormal IUD position is different . T he frequency of pregnancy and band ring are related to the occurence of adverse veactions to IUD .

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Ultrasonography Year: 2019 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Ultrasonography Year: 2019 Type: Article