Analysis of dosimetric verification results of stereotactic body radiotherapy / 中华放射医学与防护杂志
Chinese Journal of Radiological Medicine and Protection ; (12): 680-685, 2019.
Article in Chinese | WPRIM | ID: wpr-755029
ABSTRACT
Objective To analyze the patient-specific dosimetric verification result of stereotactic body radiotherapy ( SBRT ) plans, and to investigate the sensitivity of the result to three factorsinterpolation of measured data, size of dose calculation grid and assessment threshold. Methods The dosimetric verification results of SBRT plans of 50 patients were retrospectively analyzed to evaluate the impact of the following factors. The linear interpolation ( 1. 00 mm) and non-interpolation ( 7. 62 mm) were applied to measured data respectively. Three dose calculation grid sizes of Eclipse planning system, i.e., 1. 0 mm, 2. 5 mm and 4. 0 mm were compared respectively. The threshold of dose assessment was selected as 10%, 20% and 30%, respectively. Three criteria of γ analysis were selected 2%/2 mm, 3%/2 mm and 3%/3 mm. Results Under criteria of 2%/2 mm, 3%/2 mm and 3%/3 mm, the average γ passing rates were (86. 3±7. 3)% and (93. 7±5. 6)%, (94. 1±4. 4)% and(97. 7±3. 9)%, (97. 7 ±2. 2)% and (99. 1±1. 7)%, respectively, with and without linear interpolation. Relative to the 1. 0 mm reference grid, the grids of 2. 5 mm and 4. 0 mm significantly decreased γ passing rates by 3. 8%, 1. 9%, 0. 8% ( t=8. 41, 9. 06, 5. 30, P<0. 05) and by 6. 5%, 6. 0%, 3. 5% ( t=-13. 76, -13. 15, -9. 80, P<0. 05) under criteria of 2%/2 mm, 3%/2 mm and 3%/3 mm, respectively. Relative to the 10% reference threshold, the shresholds of 20% and 30% significantly decreasedγpassing rates by 2. 4%, 1. 0%, 0. 6%(t=-8. 60, -5. 86, -4. 68, P<0. 05) and by 4. 0%, 1. 7%, 0. 9% (t=-9. 45, -6. 66, -5. 06, P<0. 05) under criteria of 2%/2 mm, 3%/2 mm and 3%/3 mm, respectively. Conclusions Interpolation, dose calculation grid size and dose assessment threshold are influential factors of dose verification result, and need to be considered during dosimetric verification of stereotactic radiotherapy patients.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Radiological Medicine and Protection Year: 2019 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Radiological Medicine and Protection Year: 2019 Type: Article