Your browser doesn't support javascript.
loading
Impact of flash glucose monitoring on glycemic control in type 1 diabetic patients / 中华内分泌代谢杂志
Chinese Journal of Endocrinology and Metabolism ; (12): 383-386, 2019.
Article in Chinese | WPRIM | ID: wpr-755655
ABSTRACT
Objective The application of flash glucose monitoring ( FGM) in type 1 diabetes could diminish the frequency of hypoglycaemia, however, how FGM improving the glycaemic control target (e.g. HbA1C) is waited to be investigated. Methods Seventy type 1 diabetic patients were recruited from December 2017 to July 2018 in the First Affiliated Hospital of Nanjing Medical University. Their demographic data, use of FGM and HbA1C level were collected. Results We observed that type 1 diabetic patients wearing the FGM showed lower insulin dose [(0.562± 0.059)U/kg vs (0.772±0.049)U/kg, P=0.008)], shorter diabetic duration[2.0(0.8-6.0) vs 6.0(2.5-10), P=0.013], lower HbA1C value [6.8%(6.2%-7.7%) vs 8.0%(6.9%-9.4%), P=0.001]. Nevertheless, after adjusting the potential confounders, the level of HbA1C in patients wearing FGM was significantly lower than those without FGM. Moreover, it was independent of other factors, such as the dose of insulin and the insulin delivery method. Conclusion Type 1 diabetic patients wearing FGM had lower HbA1C value but it needs further follow-up to confirm the improvement of glycaemic control in type 1 diabetes with the use of FGM.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Endocrinology and Metabolism Year: 2019 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Endocrinology and Metabolism Year: 2019 Type: Article