Evaluation of fluoride bioavailability in toothpastes / 대한구강보건학회지
Journal of Korean Academy of Oral Health ; : 81-87, 2015.
Article in English | WPRIM | ID: wpr-75706
ABSTRACT

OBJECTIVES:

The aims of this study were to determine the total fluoride concentration and bioavailable fluoride concentration in different toothpastes, based on a newly suggested method by the International Organization for Standardization (ISO), and to compare the measured concentrations with the concentrations written on the packaging.

METHODS:

The concentrations of total fluoride (TF) and bioavailable fluoride (BF) were measured in six toothpastes. For the TF measurement, 1 g of each toothpaste was mixed with dipotassium hydrogen phosphate (K2HPO4), and hydrogen chloride (HCl) was placed. After 24 hours, the samples were centrifuged and total ionic strength adjustment buffer (TISAB) solution was added. For the BF measurement, the toothpaste was mixed with K2HPO4 for only 1 minute. The samples were centrifuged, and then HCl was placed and allowed to stand for 24 hours. The TISAB solution was added subsequently. The concentration of fluoride ions was measured using a fluoride ion-selective electrode and calculated against a standard curve.

RESULTS:

The six toothpastes were composed of different fluoride compounds and abrasives. The measured TF concentration ranged from 624.99 ppm to 1,353.00 ppm, and the similarity to the declared fluoride concentration ranged from 53.48% to 93.31%. The measured BF concentration ranged from 587.61 ppm to 1,360.05 ppm, and the similarity to the expected fluoride concentration ranged from 41.97% to 93.80%. Two samples were clearly separated when the samples were centrifuged, whereas the remaining four samples had unclear supernatants. The clearly separated toothpastes (i.e., toothpastes 5 and 6) had BF concentrations that were similar to or lower than the declared fluoride concentrations and the measured TF concentrations. However, the unclearly separated toothpastes showed inconsistent relationships between the measured TF and BF concentrations.

CONCLUSIONS:

The measured TF and BF concentrations of the six toothpastes did not reach the expected fluoride concentration. This finding resulted from the different compositions and forms of the toothpastes. Therefore, the properties of toothpastes need to be considered when measuring their fluoride concentrations.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Osmolar Concentration / Toothpastes / Biological Availability / Ion-Selective Electrodes / Product Packaging / Fluorides / Hydrochloric Acid / Hydrogen / Ions Language: English Journal: Journal of Korean Academy of Oral Health Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Osmolar Concentration / Toothpastes / Biological Availability / Ion-Selective Electrodes / Product Packaging / Fluorides / Hydrochloric Acid / Hydrogen / Ions Language: English Journal: Journal of Korean Academy of Oral Health Year: 2015 Type: Article