The effects of saline soaking on the removal torque of titanium implants in rabbit tibia after 10 days / 대한치과보철학회지
The Journal of Korean Academy of Prosthodontics
;
: 328-334, 2019.
Article
in English
| WPRIM
| ID: wpr-761461
ABSTRACT
PURPOSE:
The aim of this study was to confirm if Laser-treated implants were soaked in 0.9% NaCl solution for 2 weeks could increase the surface hydrophilicity, and the Remoal Torque of each implant that inserted in rabbit tibia for initial healing period of 10 days. MATERIALS ANDMETHODS:
Twenty machined titanium surface screws were produced with a diameter 3 mm, length 8 mm. Ten screws had their surface treated with a laser only (laser treated group), and the other 10 were soaked in saline for 2 weeks after surface treatment with a laser (laser treated + saline soaked group). Implants were inserted in rabbit tibia (ten adult New Zealand white rabbits), and the RTQ of each implant was measured after 10 days. The wettability among implants was compared by measuring the contact angle. Surface composition and surface topography were analyzed.RESULTS:
After 10 days, the laser treat + soaking group implants had a significantly higher mean RTQ than the laser treated implants (P = .002, < .05). There were no significant morphological differences between groups, and no remarkable differences were found between the two groups in the SEM analysis.CONCLUSION:
Saline soaking implants is expected to produce excellent RTQ and surface analysis results.
Full text:
Available
Index:
WPRIM (Western Pacific)
Main subject:
Tibia
/
Titanium
/
Wettability
/
Torque
/
Hydrophobic and Hydrophilic Interactions
/
New Zealand
Limits:
Adult
/
Humans
Country/Region as subject:
Oceania
Language:
English
Journal:
The Journal of Korean Academy of Prosthodontics
Year:
2019
Type:
Article
Similar
MEDLINE
...
LILACS
LIS