Surgical Removal of the Inferior Vena Cava Filter Using Minimal Cavotomy: A Case Report
Vascular Specialist International ; : 48-51, 2019.
Article in English | WPRIM | ID: wpr-762000
ABSTRACT
The use of retrievable inferior vena cava (IVC) filters has markedly increased in the recent years. However, the failure rate for the retrieval of the IVC filters using the endovascular method is reported to be up to 19%. Open surgical removal of the IVC filters is technically challenging and may require longitudinal cavotomy, clamping, and repair of the IVC. Here, we present a case of successful open surgical removal of the IVC filter using minimal cavotomy. This technique is an effective method after a failed endovascular removal attempt.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Vena Cava, Inferior / Vena Cava Filters / Constriction / Methods Language: English Journal: Vascular Specialist International Year: 2019 Type: Article