A “Back Light System” for Identification of Sites for Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Solid Pancreatic Masses: A Prospective, Randomized Study with a Crossover Design
Clinical Endoscopy ; : 334-339, 2019.
Article in English | WPRIM | ID: wpr-763456
ABSTRACT
BACKGROUND/

AIMS:

We applied a back light system (BLS) with a magnifying glass to improve the ability to assess the adequacy of specimen sampling using endosonography. We conducted this study to evaluate the efficacy of the BLS in sampling of specimens by endoscopic ultrasound-guided fine needle aspiration of solid pancreatic masses.

METHODS:

This was a prospective, randomized, crossover, single-center clinical trial. An endosonographer evaluated adequacy on gross visual inspection and identified whitish specimen sampling sites with and without the BLS according to a randomization sequence in the first and second passes with a 25-G needle. On cytological evaluation, the presence of well-defined pancreatic ductal epithelium was evaluated by a cytopathologist who was blinded to any clinical information.

RESULTS:

A total of 80 consecutive patients were eligible during the study period. Adequacy was observed for 52 specimens (65%) with the BLS and 54 (68%) without the BLS (p=0.88). In assessment of specimen adequacy on gross examination, only fair agreement was observed both with and without BLS (kappa score 0.40 and 0.29, respectively).

CONCLUSIONS:

The BLS did not influence the ability to identify specimen sampling sites or reliable assessment of specimen site adequacy using gross visual inspection.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Pancreatic Ducts / Pancreatic Neoplasms / Random Allocation / Prospective Studies / Cross-Over Studies / Endosonography / Biopsy, Fine-Needle / Epithelium / Endoscopic Ultrasound-Guided Fine Needle Aspiration / Glass Type of study: Controlled clinical trial / Diagnostic study / Observational study / Prognostic study Limits: Humans Language: English Journal: Clinical Endoscopy Year: 2019 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Pancreatic Ducts / Pancreatic Neoplasms / Random Allocation / Prospective Studies / Cross-Over Studies / Endosonography / Biopsy, Fine-Needle / Epithelium / Endoscopic Ultrasound-Guided Fine Needle Aspiration / Glass Type of study: Controlled clinical trial / Diagnostic study / Observational study / Prognostic study Limits: Humans Language: English Journal: Clinical Endoscopy Year: 2019 Type: Article