Histomorphometric study of dental implants with double acid-etched and anodic oxidized surface in the rabbit tibia
Journal of the Korean Association of Maxillofacial Plastic and Reconstructive Surgeons ; : 434-444, 2006.
Article in Korean | WPRIM | ID: wpr-784709
ABSTRACT
treatments to the bone formation during osseous healing period under unloading conditions. Machined, double-acid etched and anodic oxidized implants were inserted into tibia of 3.0 - 3.5 kg NZ white male rabbits and 2 animals of each group were sacrificed at 2, 4 and 8 weeks. The specimens containing implant was dehydrated and embedded into hard methylmethacrylate plastic. After grinding to 50micrometer, the specimens were stained with Villanueva bone stain. From each specimen, histomorphometric evaluation and the bone implant contact rate were analysed with optical microscope. The results were as follows; 1. In the scanning electronic microscopic examination, machined surface implant had several shallow and paralleled scratches on plain surface, double acid-etched implant had lots of minute wrinkles, rough valley and also irregularly located craters that looked like waves, anodic oxidized surface implant had porosity that minute holes were wholly distributed on the surface. 2. After 2 weeks of implantation, the percentages of bone-to-implant contact in the machined implant, double acid-etched implant and anodic oxidized implant were 26.85%, 62.64% and 59.82%, after 4 weeks of implantation they were 64.29%, 77.85% and 75.23%, and after 8 weeks they were 82.66%, 85.34% and 86.39%. 3. After 2 weeks of implantation, the percentages of bone area between threads in the machined implant, double acid-etched implant and anodic oxidized implant were 21.55%, 42.81%, and 40.33%, after 4 weeks of implantation they were 49.32%, 62.60% and 75.56%, and after 8 weeks they were 71.62%, 87.73% and 83.94%. In summary, percentages of implant surface contacted to bone trabeculae and bone formation area inside threads in double acid-etched implants and anodic oxidized implants were greater than machined implants in early healing stage. These results suggest that double acid-etched and anodic oxidized surface implants could reduce the healing period for osseointegration and may enable to do early function.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Osteogenesis / Plastics / Tibia / Dental Implants / Osseointegration / Porosity / Methylmethacrylate Limits: Animals / Humans / Male Language: Korean Journal: Journal of the Korean Association of Maxillofacial Plastic and Reconstructive Surgeons Year: 2006 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Osteogenesis / Plastics / Tibia / Dental Implants / Osseointegration / Porosity / Methylmethacrylate Limits: Animals / Humans / Male Language: Korean Journal: Journal of the Korean Association of Maxillofacial Plastic and Reconstructive Surgeons Year: 2006 Type: Article