Your browser doesn't support javascript.
loading
Interobserver variations in the delineation of planning target volume and with orgagans at risk different contouring methods in intensity-modulated radiation therapy for nasopharyngeal carcinoma / 中华放射肿瘤学杂志
Chinese Journal of Radiation Oncology ; (6): 762-766, 2019.
Article in Chinese | WPRIM | ID: wpr-796678
ABSTRACT
Objective@#To assess the interobserver variations in delineating the planning target volume (PTV) and organs at risk (OAR) using different contouring methods during intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC), aiming to provide references for the quality control of multi-center clinical trials.@*Methods@#The PTV and OAR of CT image of 1 NPC patient manually delineated by 10 physicians from 8 different radiation centers were defined as the " manual contour group" , and the OAR auto-contoured using the ABAS software and modified by the physicians were defined as the " auto+ manual contour group" . The maximum/minimum ratio (MMR) of the PTV and OAR volumes, and the coefficient of variation (CV) for different delineated contours were comparatively evaluated.@*Results@#Large variation was observed in the PTV and OAR volumes in the manual contour group. The MMR and CV of the PTV were 1.72-3.41 and 0.16-0.39, with the most significant variation in the PTVnd (MMR=3.41 and CV=0.39 for the PTVnd-L). The MMR and CV of the manually contoured OAR were 1.30-7.89 and 0.07-0.67. The MMR of the temporal lobe, spinal cord, temporomandibular joint, optic nerve and pituitary gland exceeded 2.0. Compared with the manual contour group, the average contouring time in the auto+ manual group was shortened by 68% and the interobserver variation of the OAR volume was reduced with an MMR of 1.04-2.44 and CV of 0.01-0.37.@*Conclusions@#Large variation may occur in the PTV and OAR contours during IMRT plans for NPC delineated by different clinicians from multiple medical centers. Auto-contouring+ manually modification can reduce the interobserver variation of OAR delineation, whereas the variation in the delineation of small organs remains above 1.5 times. The consistency of the PTV and OAR delineation and the possible impact upon clinical outcomes should be reviewed and evaluated in multi-center clinical trials.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Etiology study / Practice guideline Language: Chinese Journal: Chinese Journal of Radiation Oncology Year: 2019 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Etiology study / Practice guideline Language: Chinese Journal: Chinese Journal of Radiation Oncology Year: 2019 Type: Article