Combining 3D heads-up display viewing system and intraoperative optical coherence tomography-assisted vitrectomy for myopic foveoschisis / 中华眼底病杂志
Chinese Journal of Ocular Fundus Diseases ; (6): 529-533, 2019.
Article in Chinese | WPRIM | ID: wpr-805488
ABSTRACT
Objective@#To observe the clinical efficacy of digital 3D heads-up display viewing system(3D viewing system) and intraoperative OCT (iOCT) in vitrectomy for myopic foveoschisis (MF).@*Methods@#A retrospective, consecutive case series. From October 2018 to May 2019, Nineteen eyes of 19 consecutive patients with MF diagnosed in Xiamen Eye Center of Xiamen University who underwent vitrectomy were included in this study. There were 7 males and 12 females, with the mean age of 54.47±11.38 years. The average axial length was 30.40±2.30 mm, the mean logMAR BCVA was 0.56±0.31, the mean central foveal thickness (CFT) was 317.80±151.9.32 μm, the mean max retinal thickness (maxRT) was 556.7±143.7 μm. All the surgeries performed combined with 3D viewing system with iOCT. The standard 25G pars planar vitrectomy were performed with removing the posterior vitreous and indocyanine green (ICG) staining of internal limiting membrane (ILM) and air-fluid exchange. Thirteen of 19 eyes underwent fovea-sparing ILM peeling and the other 6 eyes not. The average follow-up was 4.2±1.4 months. All the patients were on regular follow-up to document the changes on BCVA, anatomical changes in macula, CFT and maxRT. Paired t test was used to compare BCVA, CFT and maxRT before and after surgery.@*Results@#The fine images of macula were clearly shown on the 3D viewing system in all eyes. The electronic green filter enhanced the contrast sensitivity of ICG stained images. Clear images of macula were captured by iOCT in all eyes. The average surgical time was 35.5±8.2 min. On the last follow-up, 16 of 19 eyes with MF resolved. The mean CFT was 178.5±103.5 μm, the maxRT was 341.8±83.8.16 μm, and the mean logMAR BCVA was 0.35±0.22. The differences of CFT, maxRT and logMAR BCVA before and after surgery were statistically significant (t=4.181, 7.154, 5.129; P<0.001). Minimal invisible full thickness macular hole were detected in 2 eyes by iOCT and repaired with auto serum or ILM flap covering. There was no complication associated with the 3D viewing system.@*Conclusions@#3D viewing system provides improved contrast and crystal clear macular image stain with ICG in pathological myopia. iOCT can detect the minimal invisible full thickness macular hole during surgery. Both may contribute to improved MF closure rate and BCVA.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Ocular Fundus Diseases Year: 2019 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Ocular Fundus Diseases Year: 2019 Type: Article