Clinical retrospective study of navigation guided impacted maxillary supernumerary tooth extraction / 中华口腔医学杂志
Chinese Journal of Stomatology
;
(12): 103-106, 2018.
Article
in Chinese
| WPRIM
| ID: wpr-806021
ABSTRACT
Objective@#To analyze the efficiency and safety of navigation guided extraction of impacted supernumerary tooth.@*Methods@#Twenty-five cases of navigation guided supernumerary tooth extraction and 25 cases of non-navigation guided supernumerary tooth extraction (control group) were included in the study. Each group had 3 cases with one impacted supernumerary tooth and 22 cases with two impacted teeth.@*Results@#Preoperative navigation system designing time was (45.0±8.0) min in average. Navigation system installation time was (15.0±2.8) min. The average operation time was (0.64±0.08) hour in navigation group and (0.91±0.09) hour in control group.@*Conclusions@#Navigation guided extraction of impacted supernumerary tooth takes less time for operation but more time for the preoperative navigation system design.