Consistency evaluation of thyroid stimulating hormone results from 4 chemiluminescence assays / 临床检验杂志
Chinese Journal of Clinical Laboratory Science
; (12): 62-66, 2019.
Article
in Zh
| WPRIM
| ID: wpr-821259
Responsible library:
WPRO
ABSTRACT
Objective@#To compare the consistency of thyroid stimulating hormone (TSH) results from four chemiluminescence assays. @*Methods@#A total of 102 fresh serum samples from Peking Union Medical College Hospital during March 2018 and April 2018 were collected for precision evaluation and methodological comparison referring to CLSI EP15-A2 and EP9-A2 protocols. The levels of serum TSH were detected by Abbott i2000 (system A), Beckman DXI800 (system B), Siemens ADVIA Centaur XP (system C) and Roche e601 (system D) automatic chemiluminescence analyzers and their matching reagents, respectively. The obtained results were compared with the passing-bablok and Bland Altman methods. Taking 0.27 μIU/mL and 5.33 μIU/mL as the medical decision level, the expected bias of each detection system was compared. @*Results@#The precisions of systems A,B,C and D were 1.7%-3.3%, 2.3%- 3.9%,0.7%-2.3% and 0.6%-1.5%,respectively. The median (P 25,P 75) of TSH concentrations detected by systems A,B,C and D were 1.898 (0.518,4.809)μIU/mL, 2.819 (0.719,7.020)μIU/mL,2.502 (0.692,6.888)μIU/mL and 3.105 (0.886, 7.905)μIU/mL, respectively. The coefficients of determination (R 2 ) of regression equation were above 0.975 for 4 detection systems. The correlation coefficients (r), intercepts and slopes of 4 detection systems were 0.993 5-0.997 1, 0-0.06 and 0.59-1.15, respectively, and systems B and C had the best correlations with 1.02 of slope and 0 of intercept. The deviation plot showed that the bias% of 4 detection systems was between -48.1% and 17.3%. Among them, systems A and D had the largest bias, while systems B and C had the lowest bias. The expected bias of 4 detection systems at the medical decision level was -40.7%-37.2%. @*Conclusion@#The consistency between Beckman and Siemens TSH detection systems is good, while those of Roche and Abbott TSH detection systems are different from the other two.
Full text:
1
Index:
WPRIM
Language:
Zh
Journal:
Chinese Journal of Clinical Laboratory Science
Year:
2019
Type:
Article