Your browser doesn't support javascript.
loading
Removal of a Trigger Cord Stuck between Bands during Endoscopic Multiple-Band Ligation for Treating Esophageal Variceal Hemorrhage
Clinical Endoscopy ; : 230-231, 2020.
Article | WPRIM | ID: wpr-832165
ABSTRACT
Endoscopic variceal ligation is the preferred endoscopic treatment method for esophageal variceal bleeding. The incidence of complications such as chest pain, bleeding, stricture formation, and aspiration pneumonia is low. We report a case wherein a malfunctioning multiple-band ligator could have potentially caused damage to the esophageal varices and massive bleeding. The equipment was safely removed using scissors and forceps. To the best of our knowledge, this is the first published report detailing the management of a case of esophageal variceal bleeding.
Full text: Available Index: WPRIM (Western Pacific) Journal: Clinical Endoscopy Year: 2020 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Journal: Clinical Endoscopy Year: 2020 Type: Article