Your browser doesn't support javascript.
loading
Joint stability of internal conical connection abutments with or without hexagon indexes: an in vitro study
Journal of Dental Rehabilitation and Applied Science ; : 95-103, 2020.
Article | WPRIM | ID: wpr-835726
ABSTRACT
Purpose@#The purpose of this study was to compare the axial displacement of the hexagonal and conical abutment in internal conical connection implant after screw tightening and cyclic loading. @*Materials and Methods@#Internal conical connection implants were divided into two groups (n = 10) group HEX, hexagonal abutment; and group CON, conical 2-piece abutments. The axial displacement and removal torque values were measured after 30 Ncm torque tightening and 250N loading test of 100,000 cycles. The Student t test with 5% significance level was used to evaluate the data. @*Results@#HEX group demonstrated significantly higher axial displacement values after 30 Ncm tightening in comparison to the CON group (P < 0.05). No significant difference was found in axial displacement after cyclic loading (P = 0.052). Removal torque loss before and after the cyclic loading both revealed no significant difference between groups (P = 0.057 and P = 0.138). Removal torque value decreased after cyclic loading in both groups (P < 0.05). @*Conclusion@#Overall, both abutment with or without hexagon index presented similar biomechanical performance except HEX group demonstrated significantly more axial displacement after applying tightening torque.
Full text: Available Index: WPRIM (Western Pacific) Journal: Journal of Dental Rehabilitation and Applied Science Year: 2020 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Journal: Journal of Dental Rehabilitation and Applied Science Year: 2020 Type: Article