Intraocular Pressure Assessment in Vitrectomized Gas-filled Eyes
Journal of the Korean Ophthalmological Society ; : 1378-1383, 1995.
Article in Korean | WPRIM | ID: wpr-84470
ABSTRACT
We assessed the accuracy of Goldmann or Schi-(phi)tz tonometric readings in the gas filled vitrectomized eyes. We performed pars plana vitrectomy with or without lensectomy in 8 rabbit eyes, and in 6 enucleated porcine eyes. Fluid-air exchange was done at the end of the procedure. Intraocular pressure was measured using Goldmann tonometer and Schi-(phi)tz tonometer and was compared with true pressure which was monitored by manometer with indwelling catheter in the intravitreal cavity. Goldmann and Schi-(phi)tz tonometry always showed lower presure value than manometeric one(P0.05).
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Reading / Vitrectomy / Catheters, Indwelling / Intraocular Pressure / Manometry Language: Korean Journal: Journal of the Korean Ophthalmological Society Year: 1995 Type: Article