Your browser doesn't support javascript.
loading
Comparison of the standard and long-stem bone cement prosthesis replacement in the treatment of intertrochanteric fractures in elderly patients / 中国组织工程研究
Chinese Journal of Tissue Engineering Research ; (53): 362-367, 2021.
Article in Chinese | WPRIM | ID: wpr-847197
ABSTRACT

BACKGROUND:

The choice of standard femoral prosthesis or lengthened femoral prosthesis for the treatment of femoral intertrochanteric fracture in the elderly with hemihip replacement has always troubled clinicians.

OBJECTIVE:

To compare the short-term clinical efficacy of standard and long-stem prosthesis replacement in the treatment of elderly comminuted intertrochanteric Jensen V fractures.

METHODS:

Data of 216 elderly patients with comminuted intertrochanteric femoral Jensen V fractures undergoing bone cement artificial half hip arthroplasty in Loudi Central Hospital from January 2008 to January 2019 were retrospectively analyzed. According to the type of prosthesis, the patients were divided into standard stem prosthesis placement group (n=92) and long-stem prosthesis replacement group (n=124). According to the fracture situation, the wire Kirschner wire was used to reduce the trochanteric fracture. At 1 year after surgery, Hariss score of the hip joint was evaluated. X-ray examination was used to observe imaging manifestations around the prosthesis. RESULTS AND

CONCLUSION:

(1) Two patients in the standard stem prosthesis placement group died; three patients in the long-stem prosthesis replacement group died. The remaining patients were followed up for 12-24 months. (2) At 1 year after surgery, Hariss scores were (88.6±2.9) in the standard stem prosthesis placement group with an excellent and good rate of 83.3%, and (86.9±2.7) in the long-stem prosthesis replacement group with an excellent and good rate of 82.6%; no significant difference was found between the two groups (P > 0.05). (3) In the standard stem prosthesis placement group, one case affected femoral greater trochanteric fracture nonunion; two cases had femoral small trochanteric fracture nonunion; two cases experienced Brooker’s grade 1 heterotopic ossification. In the long-stem prosthesis replacement group, one case affected femoral greater trochanteric fracture nonunion; three cases had femoral small trochanteric fracture nonunion; two cases experienced Brooker’s grade 1 heterotopic ossification. There was no significant difference in the incidence of complications between the two groups (P > 0.05). (4) It is indicated that the short-term clinical efficacy of standard and long-stem cement-type prosthesis replacement in the treatment of Jensen V type trochanteric fracture in elderly patients is satisfactory, with no statistical difference, but the long-term effect remains to be studied.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Tissue Engineering Research Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Tissue Engineering Research Year: 2021 Type: Article