Your browser doesn't support javascript.
loading
Application of anterior subcutaneous internal fixator combined with posterior plate in treatment of unstable pelvic fractures / 中国修复重建外科杂志
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 878-882, 2020.
Article in Chinese | WPRIM | ID: wpr-856290
ABSTRACT

Objective:

To investigate the effectiveness of anterior subcutaneous internal fixator combined with posterior plate in the treatment of unstable pelvic fractures.

Methods:

Between January 2015 and January 2019, 26 cases of unstable pelvic fractures were treated with anterior subcutaneous internal fixator combined with posterior plate. There were 16 males and 10 females, with an average age of 42.8 years (range, 25-66 years). According to the Tile classification, 9 of them belonged to type B2, 6 to type B3, 7 to type C1, 3 to type C2, 1 to type C3. The injury severity score (ISS) was 6-43 (mean, 18.3). Four cases combined with brain injury, 7 with limb fractures, 3 with hemopneumothorax, 1 with sciatic nerve injury. The time from injury to operation was 4-12 days (mean, 6.4 days). The intraoperative blood loss, operation time, and the complications were recorded. The fracture reduction and the postoperative function of patients were evaluated.

Results:

All patients were followed up 12-26 months (mean, 16.8 months). The operation time was 65-142 minutes (mean, 72.5 minutes) and the intraoperative blood loss was 42-124 mL (mean, 64.2 mL). There were 2 cases of unilateral lateral femoral cutaneous nerve stimulation, 1 case of femoral nerve paralysis, and 1 case of superficial infection of incision, which were cured after corresponding treatment. X-ray films showed that all fractures healed at 3 months after operation. At last follow-up, according to Matta criteria for fracture reduction, the results were excellent in 8 cases, good in 15 cases, fair in 2 cases, and poor in 1 case, with an excellent and good rate of 88.5%. According to Majeed scoring system for pelvic function, the results were excellent in 10 cases, good in 12 cases, and fair in 4 cases, with an excellent and good rate of 84.6%.

Conclusion:

For unstable pelvic fractures, the anterior subcutaneous internal fixator combined with posterior plate has fewer operative complications, high security, and achieve good effectiveness.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Reparative and Reconstructive Surgery Year: 2020 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Reparative and Reconstructive Surgery Year: 2020 Type: Article