Your browser doesn't support javascript.
loading
Diagnostic accuracy of urine dipstick for proteinuria in older outpatients
Kidney Research and Clinical Practice ; : 199-203, 2014.
Article in English | WPRIM | ID: wpr-86005
ABSTRACT

BACKGROUND:

The urine dipstick is widely used as an initial screening tool for the evaluation of proteinuria; however, its diagnostic accuracy has not yet been sufficiently evaluated. Therefore, we evaluated its diagnostic accuracy using spot urine albumin/creatinine ratio (ACR) and total protein/creatinine ratio (PCR) in proteinuria.

METHODS:

Using PCR > or = 0.2g/g or > or = 0.5g/g and ACR > or = 300mg/g or > or = 30mg/g as the reference standard, we calculated the diagnostic accuracy profile sensitivity, specificity, positive and negative predictive value, and the area under the curve (AUC) of the receiver operating characteristic curve.

RESULTS:

PCR and ACR were available for 10,348 and 3,873 instances of dipstick testing. The proportions with PCR > or = 0.2g/g, > or = 0.5g/g and ACR > or = 300mg/g, > or = 30mg/g were 38.2%, 24.6% and 8.9%, 31.7%, respectively. The AUCs for PCR > or = 0.2g/g, > or = 0.5g/g, and ACR > or = 300mg/g were 0.935 (trace closest to ideal point), 0.968 (1+), and 0.983 (1+), respectively. Both sensitivity and specificity were > 80% except for PCR > or = 0.5g/g with trace cutoff. For the reference standard of ACR > or = 30mg/g, the AUC was 0.797 (trace) and the sensitivity was 63.5%.

CONCLUSION:

Urine dipstick test can be used for screening in older outpatients with ACR > or = 300mg/g or PCR as the reference standard for proteinuria. However, we cannot recommend the test as a screening tool with ACR > or = 30mg/g as the reference owing to its low sensitivity.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Outpatients / Proteinuria / Reagent Strips / Mass Screening / Polymerase Chain Reaction / ROC Curve / Sensitivity and Specificity / Area Under Curve / Albuminuria Type of study: Diagnostic study / Prognostic study / Screening study Limits: Humans Language: English Journal: Kidney Research and Clinical Practice Year: 2014 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Outpatients / Proteinuria / Reagent Strips / Mass Screening / Polymerase Chain Reaction / ROC Curve / Sensitivity and Specificity / Area Under Curve / Albuminuria Type of study: Diagnostic study / Prognostic study / Screening study Limits: Humans Language: English Journal: Kidney Research and Clinical Practice Year: 2014 Type: Article