Your browser doesn't support javascript.
loading
Numerical Simulation on Support Performance of NiTi Alloy Thoracic Aortic Stent / 医用生物力学
Journal of Medical Biomechanics ; (6): E410-E414, 2020.
Article in Chinese | WPRIM | ID: wpr-862362
ABSTRACT
Objective To study the influence of different support heights, support numbers and cross-sectional dimensions on support performance of NiTi thoracic aortic stents. Methods Twenty-seven scaffold models with different parameters were established by using AutoCAD 2016 and SoildWorks 2014 software. HyperMesh 14.0 was used for tetrahedral mesh division, and ABAQUS 2017 was used for support performance simulation analysis. Results With the decrease of support height, the support stiffness would increase; a larger cross-section size would lead to a larger support stiffness; with the increase of support numbers, the support stiffness would increase. Among the influencing factors of support performance, the order of influence degree was support height>section size>support numbers. Conclusions The research findings have certain guiding significance for the development and research of thoracic aortic stents, and provide theoretical basis for the selection and optimization of clinical stents.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Prognostic study Language: Chinese Journal: Journal of Medical Biomechanics Year: 2020 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Prognostic study Language: Chinese Journal: Journal of Medical Biomechanics Year: 2020 Type: Article