Effect of crystalline lens rise on the vault after implantation of phakic posterior chamber implantable collamer lens / 国际眼科杂志(Guoji Yanke Zazhi)
International Eye Science
;
(12): 377-381, 2021.
Article
in Chinese
| WPRIM
| ID: wpr-862448
ABSTRACT
@#AIM:
To investigate the relationship between crystalline lens rise(CLR)measured by anterior segment-optical coherence tomography(AS-OCT)and parameters of the anterior segment. And also measure the effects of CLR on the vault after phakic posterior chamber implantable collamer lens(PPC-ICL)implantation.<p>METHODS:
The study included 80 eyes of 40 patients who underwent PPC-ICL implantation at the Department of Ophthalmology, the Second Affiliated Hospital of Anhui Medical University, from July 2017 to July 2018, to measure the sulcus-to-sulcus(hSTS)distance of the eyes using a Compact Touch STS ultrasound biomicroscope and lens curvature(LC), Pentacam was used to measure horizontal-white-to-white(hWTW), anterior chamber depth(ACD)and the vault one year after the operation. Moreover, AS-OCT was used to measure the CLR and horizontal iridocorneal angle-to-iridocorneal angle diameter(ATA).<p>RESULTS:
CLR was negatively correlated with ACD(<i>r</i>= -0.706, <i>P</i><0.01)and vault one year after the operation(<i>r</i>= -0.509, <i>P</i><0.01); however, it was positively correlated with LC(<i>r</i>=0.667, <i>P</i><0.01). There was no correlation between CLR and hWTW(<i>r</i>=0.123, <i>P</i>=0.275), ATA(<i>r</i>=0.208, <i>P</i>=0.065)and hSTS(<i>r</i>=0.147, <i>P</i>=0.194). One year after the operation, there was a positive correlation between the vault and ACD(<i>r</i>=0.680, <i>P</i><0.01).<p>CONCLUSION:
CLR has obvious correlation with ACD and LC, arch height after PPC-ICL and has a specific effect on the prediction of the vault after PPC-ICL implantation.
Full text:
Available
Index:
WPRIM (Western Pacific)
Language:
Chinese
Journal:
International Eye Science
Year:
2021
Type:
Article
Similar
MEDLINE
...
LILACS
LIS