Coracoclavicular Screw Fixation and Tension Band Wiring in Treatment of Distal Clavicle Fracture
Journal of the Korean Fracture Society
;
: 1-7, 2013.
Article
in Korean
| WPRIM
| ID: wpr-86373
ABSTRACT
PURPOSE:
The purpose of this study was to analyze the effectiveness of coracoclavicular screw fixation with tension band wiring in the treatment of displaced distal clavicle fractures. MATERIALS ANDMETHODS:
From October 2006 to December 2010, 18 patients with Neer type 2 displaced distal clavicle fracture were surgically treated. Fixation was performed, using coracoclavicular screw with tension band wiring. Radiographic and clinical evaluation was performed and the University of California at Los Angeles (UCLA) shoulder rating scale was employed for the assessment of shoulder joint function.RESULTS:
Osseous union was achieved approximately 9.5 weeks (8-11 weeks) in all patients. After the union, the screw and wire were removed under local anesthesia. All patients returned to the normal shoulder range of motion. Loosening of the screw was seen in two patients and breakage was seen in one patient. However, we could not observe the delayed union and complications, such as infection and refracture. All but one patient showed excellent results according to the UCLA shoulder score at one year after the operation.CONCLUSION:
Coracoclavicular screw fixation with tension band wiring in the treatment of displaced distal clavicle fractures is a clinically useful technique with good result and less complication.
Full text:
Available
Index:
WPRIM (Western Pacific)
Main subject:
Shoulder
/
Shoulder Joint
/
Los Angeles
/
California
/
Range of Motion, Articular
/
Clavicle
/
Anesthesia, Local
Type of study:
Diagnostic study
Limits:
Humans
Country/Region as subject:
North America
Language:
Korean
Journal:
Journal of the Korean Fracture Society
Year:
2013
Type:
Article
Similar
MEDLINE
...
LILACS
LIS