Comparison the value of parotid and submandibular gland scintigraphy for the diagnosis of Sj?gren's syndrome using Shizukuishi scoring method / 中华风湿病学杂志
Chinese Journal of Rheumatology ; (12): 660-663,c10-1, 2020.
Article in Zh | WPRIM | ID: wpr-868244
Responsible library: WPRO
ABSTRACT
Objective:Shizukuishi scoring method was used to compare the diagnostic value of parotid gland and submandibular gland scintigraphy for Sj?gren's syndrome (SS).Methods:Parotid gland and submandibular gland scintigraphy were conducted in 124 SS patients and 91 control subjects respectively, the results of scintigraphy of each gland were evaluated by excretion rate and 0-3 points per gland, the diagnostic accuracy of parotid and submandibular gland scintigraphy was compared by receiver operating characteristic curve (ROC).Results:The score of parotid scintigraphy was 0-6, with the cut-off value of 2, the sensitivity for diagnosis of SS was 76.9%, the specificity was 72.6%, the area under the curve (AUC) was (0.798±0.030). The score of submandibular scintigraphy was 0-6, with the cut-off value of 2. The sensitivity for diagnosis of SS was 78.0%, the specificity was 78.2%, the area of AUC was 0.854±0.026.Conclusion:The diagno-stic value of the submandibular gland scintigraphy is good.
Full text: 1 Index: WPRIM Type of study: Diagnostic_studies / Prognostic_studies Language: Zh Journal: Chinese Journal of Rheumatology Year: 2020 Type: Article