Your browser doesn't support javascript.
loading
Valve in Valve transcatheter mitral valve replacement by a transvenous, transseptal access: A case report / 中国胸心血管外科临床杂志
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 122-124, 2021.
Article in Chinese | WPRIM | ID: wpr-873609
ABSTRACT
@#Reoperation due to degenerated bioprostheses is an important factor of high-risk thoracic surgeries. In 2020 ACC/AHA guideline, Valve in Valve (ViV) was recommended for high-risk patient instead of surgical mitral valve replacement. This report described a 77-year-old male patient with a failed mitral bioprosthetic valve, evaluated at high risk of surgery, received a transvenous, transseptal transcatheter mitral valve replacement (TMVR). Tracheal intubation was removed at CCU 3 h after surgery without discomfort such as polypnea. The patient was transferred out of the CCU and discharged on the 3rd day. Compared with transapical access, transvenous transseptal access was less invasive, with shorter duration in CCU and hospitalization.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Clinical Thoracic and Cardiovascular Surgery Year: 2021 Type: Article