Your browser doesn't support javascript.
loading
Reproducibility Analysis of Iodine Concentrations of Abdominal Parenchymal Organs Based on Spectral CT / 中国医学科学院学报
Acta Academiae Medicinae Sinicae ; (6): 57-62, 2021.
Article in Chinese | WPRIM | ID: wpr-878699
ABSTRACT
Objective To investigate the intra-and inter-observer reproducibility of iodine concentrations of abdominal parenchymal organs based on spectral CT.Methods The water-free iodine images of the venous phase were retrospectively obtained from 50 patients with abdominal dynamic spectral CT scans.The iodine concentrations were measured in the left,right and caudate lobes of liver,spleen,pancreas and bilateral kidneys.Intraclass correlation coefficient(ICC)and Bland-Altman plot were employed to analyze the intra-and inter-observer reproducibility.Results The intra-observer ICCs of the left,right and caudate lobes of liver,spleen,pancreas,and left and right kidneys were 0.938(0.894,0.965),0.932(0.884,0.961),0.939(0.895,0.965),0.947(0.909,0.970),0.912(0.851,0.949),0.946(0.906,0.969)and 0.907(0.842,0.946),which indicated good intra-observer reproducibility.The inter-observer ICCs of the left,right and caudate lobes of liver,spleen,pancreas,and left and right kidneys were 0.947(0.909,0.970),0.927(0.875,0.958),0.943(0.902,0.968),0.956(0.924,0.975),0.934(0.887,0.962),0.927(0.875,0.958)and 0.892(0.818,0.937),which indicated good inter-observer reproducibility.Bland-Altman plots presented that more than 95% points of the intra-observer differences located within 95% CI of limits of agreement for the caudate lobe of liver,spleen,pancreas and bilateral kidneys,which was same as inter-observer differences of the caudate lobe of liver,spleen and right kidney.Conclusion The iodine concentration measurement based on the spectral CT presented good intra-and inter-observer reproducibility for the caudate lobe of liver and spleen.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Tomography, X-Ray Computed / Observer Variation / Reproducibility of Results / Retrospective Studies / Iodine Type of study: Observational study Limits: Humans Language: Chinese Journal: Acta Academiae Medicinae Sinicae Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Tomography, X-Ray Computed / Observer Variation / Reproducibility of Results / Retrospective Studies / Iodine Type of study: Observational study Limits: Humans Language: Chinese Journal: Acta Academiae Medicinae Sinicae Year: 2021 Type: Article