Your browser doesn't support javascript.
loading
Detecting ethylene glycol monopropyl ether in workplace air by solvent desorption-gas chromatography / 中国职业医学
China Occupational Medicine ; (6): 91-94, 2018.
Article in Chinese | WPRIM | ID: wpr-881671
ABSTRACT

OBJECTIVE:

To develop a solvent desorption-gas chromatography method for detecting ethylene glycol monopropyl ether( EGME) in workplace air.

METHODS:

EGME in workplace air was captured by charcoal tubes and desorbed by methanol-methylene chloride(5∶ 95,V/V),separated by capillary chromatographic column,and detected by flame ionization detector.

RESULTS:

The good linear range of EGME was 1. 37-1 913. 80 mg/L,and the correlation coefficient was 0. 999 90. The detection limit was 0. 06 mg/L. The minimum detectable concentration was 0. 02 mg/m3.The average desorption efficiency was 97. 81%-104. 70%. The within-run relative standard deviation( RSD) was 1. 94%-2. 99%,and the between-run RSD was 3. 24%-4. 53%. The samples could be stored at room temperature for at least 14 days.

CONCLUSION:

This method could be used for detection of EGME in workplace air.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Occupational Medicine Year: 2018 Type: Article