Your browser doesn't support javascript.
loading
Characteristics of nailfold capillaroscopy in fine sanding workers / 中国职业医学
China Occupational Medicine ; (6): 269-279, 2019.
Article in Chinese | WPRIM | ID: wpr-881788
ABSTRACT

OBJECTIVE:

To analyze the effects of hand-transmitted vibration operation on nailfold capillaroscopy( NFC) in fine sanding workers.

METHODS:

A total of 57 fine sanding workers of one golf ball production enterprise in Guangdong Province were selected as vibration exposure group and 30 workers without exposure to hand-transmitted vibration as control group by a judgement sampling method. NFC examination was carried out in workers of these two groups.

RESULTS:

The capillary haemorrhage detection rates,percentage of abnormal capillary loops and total capillary width in the vibration exposure group were higher than that in the control group [43. 9% vs 13. 3%,( 56. 6 ± 20. 9) % vs( 41. 2 ± 14. 5) %,( 44. 7 ± 4. 9) vs( 42. 4 ± 4. 9) μm,P < 0. 05]. The capillary density,capillary length and branch diameter in the vibration exposure group were lower than that in the control group [( 7. 7 ± 1. 0) vs( 8. 8 ± 1. 0) per mm,( 185. 1 ± 33. 9) vs( 205. 6 ± 23. 2) μm,( 18. 3 ± 1. 9) vs( 19. 6 ± 2. 6) μm,P < 0. 05]. No significant difference was found in the diameter of apical part and branch of capillaries between the two groups( P > 0. 05). In the vibration exposure group,the percentage of abnormal capillary loops in the left hand was lower than that in the right hand [( 53. 1 ± 20. 6) % vs( 61. 5 ±24. 2) %,P < 0. 01],the capillary length in the left hand of vibration exposure group was longer than that in the right hand [( 187. 2 ± 33. 5) vs( 179. 4 ± 35. 4) μm,P < 0. 05]. No significant difference was found in the capillary density,total capillary width,apical part diameter,output branch diameter and input branch diameter between two hands in the vibration exposure group( P > 0. 05).

CONCLUSION:

The hand-transmitted vibration can lower the nailfold capillary density,shorten and widen capillary loops, increase percentage of abnormal capillary loops and induce capillary haemorrhage. NFC could be used to assist early detection of microvascular damage induced by hand-transmitted vibration.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Screening study Language: Chinese Journal: China Occupational Medicine Year: 2019 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Screening study Language: Chinese Journal: China Occupational Medicine Year: 2019 Type: Article